YOKOGAWA AQ6377 Optical Spectrum Analyzer 1900 – 5500 nm
Teklif İsteyinYOKOGAWA AQ6377 Optical Spectrum Analyzer 1900 – 5500 nm hakkında uzman ekibimizden bilgi almak ve fiyatlar için hemen iletişime geçin!
The AQ6377 is the latest version of our optical spectrum analyzer series, offering extended wavelength coverage into the MWIR region from 1900 – 5500 nm. Its long wavelength range makes the AQ6377 ideal for environmental sensing and medical applications.
JAPON MALI
FEATURES Key Features Wavelength range: 1900 to 5500 nm 5 wavelength resolution settings: 0.2 to 5 nm Enables the user to choose the best value according to the device/system under test. Wide measurable level range: −60 to +13 dBm Suitable to measure high power as well as low power sources… Devamı
FEATURES
Key Features
- Wavelength range: 1900 to 5500 nm
- 5 wavelength resolution settings: 0.2 to 5 nm
Enables the user to choose the best value according to the device/system under test. - Wide measurable level range: −60 to +13 dBm
Suitable to measure high power as well as low power sources used in different fields of application. Sensitivity: HIGH1-3 are only high dynamic mode. - Wavelength accuracy: ±0.5 nm
Easily maintained due to the built-in Calibration Function and wavelength reference source. - Close-in dynamic range: 50 dB
Measurement example of 4.3 μm DFB laser
(Res: 0.2 nm, Span: 50 nm)
- Horizontal scale also in Wave Number (cm−1)
In addition to the commonly-used scales in wavelength (nm) and frequency (THz).
Purge Feature
Due to the high resolution and sensitivity of the AQ6377, it can actually detect the presence of water molecules in the air. The water vapor is detected in the upper Near-IR wavelength region and could overlap with or mask the spectral characteristics of the actual device under test in that particular region.
By continuously supplying a pure purge gas such as nitrogen to the monochromator through the ports on the back panel, the AQ6377 can reduce the influence of water vapor absorptions and provide more reliable and accurate measurements than ever before.
Built-in Cut Filter for High Order Diffracted Light
Due to the diffractive technology used, the monochromator in some circumstances could generate high order diffracted light, which appears at wavelengths equal to the integral multiple of input wavelengths.
By cutting incoming light below 1500 nm with the built-in filter, the AQ6377 drastically reduces the influence of high order diffracted light on the measurement. Thus, the measured data are always reliable and replicate the real signal under test.
Double Speed Mode
Increases the sweep speed up to 2 times compared to the standard sweep mode, with only a 2 dB penalty to the standard sensitivity value.
Free-Space Optical Input
The AQ6377 uses a free-space optical input structure (i.e. no fiber is mounted inside the instrument), most effective for guaranteeing high coupling efficiency, measurement repeatability, and no maintenance.
This smart solution is:
- WORRY-FREE: no internal fiber can be scratched or get dirty by inaccurate coupling of fibers
- MAINTENANCE-FREE: no internal fiber has to be cleaned
- VERSATILE: the instrument accepts both /PC and /APC connectors
- DUAL PURPOSE: the instrument accepts both Single-Mode and Multi-Mode fibers without being affected by the high insertion loss from MM-SM fibers matching
Ürün Özellikleri
Teknik Özellikler
Aksesuarlar
İlgili ürünler
YOKOGAWA AQ2200-412 Optical Switch Module (1 x 16) – Optical Switches
- Compact: Optical switches of 1 x 16 port configuration in a two-slot size module
- Compatible with SMF(10/125µm) or MMF(50/125µm)
- Low insertion loss: 1.0 dB (typ.)
- High switching reproducibility: within ±0.01 dB
- Can be combined with various AQ2200 series modules or other Yokogawa's optical communication measuring instruments to build versatile measuring systems
JAPON MALI
YOKOGAWA AQ2200-232 Optical Sensor Head (Large diameter detector, 800 to 1700 nm), AQ2200-242 Optical Sensor Head (Large diameter detector, 400 to 1100 nm), AQ2200-202 Interface Module (2-channels)
- Large-diameter detector for free-space measurement
5 mm dia. (AQ2200-232), □5.8 mm (AQ2200-242) - Multi-core connector and cable measurement
The AQ9340, AQ9436C and AQ9440Care required. - Power range: -90 to +15 dBm (AQ2200-232)
-90 to +10 dBm (AQ2200-242) - Uncertainty: ±1.8% (1310 nm, AQ2200-232)
±2.5% (850 nm, AQ2200-242) - Averaging time: 100 µm (minimum sampling intervals)
- Two sensor heads can be connected to the AQ2200-202 Interface module
JAPON MALI
YOKOGAWA AQ2200-215 Sensor module (high Power up to +30dBm, 970 to 1660 nm)
The AQ2200-215 is an optical power meter designed specifically to measure high optical power up to +30dBm. It features high speed sampling and advanced data processing functions. The AQ2200-215 is an ideal measurement tool for optical output power measurement and margin test of WDM transmission equipment, as well as gain measurements of optical fiber amplifiers. It is commonly used in conjunction with other AQ2200 Series modules and the AQ6370C Optical Spectrum Analyzer to offer a flexible customized optical measurement system.
JAPON MALI
YOKOGAWA AQ2200-131/132 Grid TLS Module (C/L band, 1-channel / 2-channel)
YOKOGAWA AQ1210 Series Optical Time Domain Reflectometer
The Yokogawa AQ1210 series OTDR tester is designed to empower field technicians to make fast and precise measurements with confidence. The AQ1210 optical time domain reflectometer delivers high reliability with its robust design for operating under harsh field conditions. Engineered with innovative technology, the AQ1210 features dual operation mode by multi-touch touchscreen and hard-key buttons as well as fully automatic measurement and easy-to-read analysis reports through new software applications. In addition, the AQ1210 enhances productivity and operability with its lightning startup time, multi-tasking operation, and immediate reporting via wireless connectivity.
JAPON MALI

