YOKOGAWA AQ6377 Optical Spectrum Analyzer 1900 – 5500 nm
Teklif İsteyinYOKOGAWA AQ6377 Optical Spectrum Analyzer 1900 – 5500 nm hakkında uzman ekibimizden bilgi almak ve fiyatlar için hemen iletişime geçin!
The AQ6377 is the latest version of our optical spectrum analyzer series, offering extended wavelength coverage into the MWIR region from 1900 – 5500 nm. Its long wavelength range makes the AQ6377 ideal for environmental sensing and medical applications.
JAPON MALI
FEATURES Key Features Wavelength range: 1900 to 5500 nm 5 wavelength resolution settings: 0.2 to 5 nm Enables the user to choose the best value according to the device/system under test. Wide measurable level range: −60 to +13 dBm Suitable to measure high power as well as low power sources… Devamı
FEATURES
Key Features
- Wavelength range: 1900 to 5500 nm
- 5 wavelength resolution settings: 0.2 to 5 nm
Enables the user to choose the best value according to the device/system under test. - Wide measurable level range: −60 to +13 dBm
Suitable to measure high power as well as low power sources used in different fields of application. Sensitivity: HIGH1-3 are only high dynamic mode. - Wavelength accuracy: ±0.5 nm
Easily maintained due to the built-in Calibration Function and wavelength reference source. - Close-in dynamic range: 50 dB
Measurement example of 4.3 μm DFB laser
(Res: 0.2 nm, Span: 50 nm)
- Horizontal scale also in Wave Number (cm−1)
In addition to the commonly-used scales in wavelength (nm) and frequency (THz).
Purge Feature
Due to the high resolution and sensitivity of the AQ6377, it can actually detect the presence of water molecules in the air. The water vapor is detected in the upper Near-IR wavelength region and could overlap with or mask the spectral characteristics of the actual device under test in that particular region.
By continuously supplying a pure purge gas such as nitrogen to the monochromator through the ports on the back panel, the AQ6377 can reduce the influence of water vapor absorptions and provide more reliable and accurate measurements than ever before.
Built-in Cut Filter for High Order Diffracted Light
Due to the diffractive technology used, the monochromator in some circumstances could generate high order diffracted light, which appears at wavelengths equal to the integral multiple of input wavelengths.
By cutting incoming light below 1500 nm with the built-in filter, the AQ6377 drastically reduces the influence of high order diffracted light on the measurement. Thus, the measured data are always reliable and replicate the real signal under test.
Double Speed Mode
Increases the sweep speed up to 2 times compared to the standard sweep mode, with only a 2 dB penalty to the standard sensitivity value.
Free-Space Optical Input
The AQ6377 uses a free-space optical input structure (i.e. no fiber is mounted inside the instrument), most effective for guaranteeing high coupling efficiency, measurement repeatability, and no maintenance.
This smart solution is:
- WORRY-FREE: no internal fiber can be scratched or get dirty by inaccurate coupling of fibers
- MAINTENANCE-FREE: no internal fiber has to be cleaned
- VERSATILE: the instrument accepts both /PC and /APC connectors
- DUAL PURPOSE: the instrument accepts both Single-Mode and Multi-Mode fibers without being affected by the high insertion loss from MM-SM fibers matching
Ürün Özellikleri
Teknik Özellikler
Aksesuarlar
İlgili ürünler
YOKOGAWA AQ1300 Series 1G/10G Ethernet Multi Field Tester
The handheld AQ 1300 ethernet field tester for network path testing and maintenance is designed to improve work efficiency and quality. The AQ1300 offers excellent functionality and operability optimized for field testing. It's easy to operate, which prevents operational errors and stabilizes work quality for routine tasks such as network path testing. Powerful analysis functions help isolate failures during maintenance work.
JAPON MALI
YOKOGAWA AQ2200-412 Optical Switch Module (1 x 16) – Optical Switches
- Compact: Optical switches of 1 x 16 port configuration in a two-slot size module
- Compatible with SMF(10/125µm) or MMF(50/125µm)
- Low insertion loss: 1.0 dB (typ.)
- High switching reproducibility: within ±0.01 dB
- Can be combined with various AQ2200 series modules or other Yokogawa's optical communication measuring instruments to build versatile measuring systems
JAPON MALI
YOKOGAWA AQ2200-332 Optical Attenuator module
- Compact: The AQ2200-332 features an optical variable attenuator and an optical power meter for monitoring the optical output power in a one-slot module. Ideal for bit error testing
- Compatible with SMF(10/125µm) or MMF(50/125µm, 62.5/125µm)
- Attenuation accuracy: within ±0.1 dB
- With the output monitoring function, the AQ2200-332 allows direct setup of optical power at the output terminals
- Can be combined with various AQ2200 series modules or other Yokogawa's optical communication measuring instruments to build versatile measuring systems
JAPON MALI
YOKOGAWA AQ2212 Frame Controller (9 Slots)
The AQ2211 and AQ2212 frame controllers are platforms for the AQ2200 Multi Application Test System. These frame controllers contain a variety of measurement applications that enable you to get the information you need without connecting an external controller PC. In addition, they have three different external interfaces, so you can always use the best interface for a particular measurement application.
- Easy-to-view color display
- USB port for data storage
- Measurement module "hot-swapping" capability
- Remote monitoring and measurement through a LAN
- See latest AQ2212 Frame Controller firmware update
JAPON MALI
YOKOGAWA AQ6151B Optical Wavelength Meter
The AQ6151B Optical Wavelength Meter is an ideal instrument for accurately measuring the optical wavelength of optical devices and systems with wavelength ranges from 900 nm to 1700 nm. By employing a Michelson interferometer and a high speed Fast Fourier Transform (FFT) algorithm, the AQ6151B can measure not only a single wavelength laser signal, but also a multiple wavelength laser signal from a DWDM system and Fabry-Perot laser. Furthermore, this technology enables the measurement of modulated laser signals in addition to the CW signal from an optical transceiver. The optimized optical design and data processing routine significantly reduces the measurement time and improves manufacturing throughput.
- High wavelength accuracy: ±0.2 ppm
- Wavelength range (3 types): 900-1700nm, 1200-1700nm, 1270-1650nm
- Measurement time of 0.2 seconds or less
- Up to 1024 wavelengths can be measured at once
- Single wavelength type and multi wavelength type
- Support modulated light and filter measurement
JAPON MALI