YOKOGAWA AQ6377 Optical Spectrum Analyzer 1900 – 5500 nm
Teklif İsteyinYOKOGAWA AQ6377 Optical Spectrum Analyzer 1900 – 5500 nm hakkında uzman ekibimizden bilgi almak ve fiyatlar için hemen iletişime geçin!
The AQ6377 is the latest version of our optical spectrum analyzer series, offering extended wavelength coverage into the MWIR region from 1900 – 5500 nm. Its long wavelength range makes the AQ6377 ideal for environmental sensing and medical applications.
JAPON MALI
FEATURES Key Features Wavelength range: 1900 to 5500 nm 5 wavelength resolution settings: 0.2 to 5 nm Enables the user to choose the best value according to the device/system under test. Wide measurable level range: −60 to +13 dBm Suitable to measure high power as well as low power sources… Devamı
FEATURES
Key Features
- Wavelength range: 1900 to 5500 nm
- 5 wavelength resolution settings: 0.2 to 5 nm
Enables the user to choose the best value according to the device/system under test. - Wide measurable level range: −60 to +13 dBm
Suitable to measure high power as well as low power sources used in different fields of application. Sensitivity: HIGH1-3 are only high dynamic mode. - Wavelength accuracy: ±0.5 nm
Easily maintained due to the built-in Calibration Function and wavelength reference source. - Close-in dynamic range: 50 dB
Measurement example of 4.3 μm DFB laser
(Res: 0.2 nm, Span: 50 nm)
- Horizontal scale also in Wave Number (cm−1)
In addition to the commonly-used scales in wavelength (nm) and frequency (THz).
Purge Feature
Due to the high resolution and sensitivity of the AQ6377, it can actually detect the presence of water molecules in the air. The water vapor is detected in the upper Near-IR wavelength region and could overlap with or mask the spectral characteristics of the actual device under test in that particular region.
By continuously supplying a pure purge gas such as nitrogen to the monochromator through the ports on the back panel, the AQ6377 can reduce the influence of water vapor absorptions and provide more reliable and accurate measurements than ever before.
Built-in Cut Filter for High Order Diffracted Light
Due to the diffractive technology used, the monochromator in some circumstances could generate high order diffracted light, which appears at wavelengths equal to the integral multiple of input wavelengths.
By cutting incoming light below 1500 nm with the built-in filter, the AQ6377 drastically reduces the influence of high order diffracted light on the measurement. Thus, the measured data are always reliable and replicate the real signal under test.
Double Speed Mode
Increases the sweep speed up to 2 times compared to the standard sweep mode, with only a 2 dB penalty to the standard sensitivity value.
Free-Space Optical Input
The AQ6377 uses a free-space optical input structure (i.e. no fiber is mounted inside the instrument), most effective for guaranteeing high coupling efficiency, measurement repeatability, and no maintenance.
This smart solution is:
- WORRY-FREE: no internal fiber can be scratched or get dirty by inaccurate coupling of fibers
- MAINTENANCE-FREE: no internal fiber has to be cleaned
- VERSATILE: the instrument accepts both /PC and /APC connectors
- DUAL PURPOSE: the instrument accepts both Single-Mode and Multi-Mode fibers without being affected by the high insertion loss from MM-SM fibers matching
Ürün Özellikleri
Teknik Özellikler
Aksesuarlar
İlgili ürünler
YOKOGAWA AQ2180 Series Portable Optical Power Meter (w/ data storage/transfer)
The compact and lightweight AQ2180 and AQ2180H optical power meters offer versatile data storage and transfer. Choose between two versions of portable electricity meters to suit test applications.
Pair the AQ2180 with the AW4280 to enable wavelength matching. The measurement wavelength on the AQ2180 can be set automatically according to the wavelength setting on the AQ4280. This feature can eliminate the extra steps to set the wavelength on the power meter and avoid improper measurements due to test wavelength mismatch.
JAPON MALI
YOKOGAWA AQ2200-312 Optical Attenuator Module
The AQ2200-312 is a variable optical attenuator type for the AQ2200 series. When it is installed in an AQ2200 series frame controller, it allows optical output to be attenuated to any value.
- Wide attenuation range:
- 0 to 60 dB (SM version)
- 0 to 45 dB (MM version)
- Wide wavelength range:
- 1200 to 1700 nm(SM version)
- 800 to 1370 nm (MM version)
- Compatible with SMF(10/125µm) or MMF(50/125µm, 62.5/125µm)
- Low insertion loss: 1.0 dB (typical)
- Low polarization dependence loss: 0.1 dBp-p or less
- Monitor output (optional)
- Configure the desired measurement system by combining AQ2200 Series modules with Yokogawa optical communications measuring instruments
JAPON MALI
YOKOGAWA AQ2200-212 Sensor Module (800 to 1700 nm)
YOKOGAWA AQ2211 Frame Controller (3 Slots)
The AQ2211 and AQ2212 frame controllers are platforms for the AQ2200 Multi Application Test System. These frame controllers contain a variety of measurement applications that enable you to get the information you need without connecting an external controller PC. In addition, they have three different external interfaces, so you can always use the best interface for a particular measurement application.
JAPON MALI
YOKOGAWA AQ6151B Optical Wavelength Meter
The AQ6151B Optical Wavelength Meter is an ideal instrument for accurately measuring the optical wavelength of optical devices and systems with wavelength ranges from 900 nm to 1700 nm. By employing a Michelson interferometer and a high speed Fast Fourier Transform (FFT) algorithm, the AQ6151B can measure not only a single wavelength laser signal, but also a multiple wavelength laser signal from a DWDM system and Fabry-Perot laser. Furthermore, this technology enables the measurement of modulated laser signals in addition to the CW signal from an optical transceiver. The optimized optical design and data processing routine significantly reduces the measurement time and improves manufacturing throughput.
- High wavelength accuracy: ±0.2 ppm
- Wavelength range (3 types): 900-1700nm, 1200-1700nm, 1270-1650nm
- Measurement time of 0.2 seconds or less
- Up to 1024 wavelengths can be measured at once
- Single wavelength type and multi wavelength type
- Support modulated light and filter measurement
JAPON MALI