Facebook Email Instagram linkedin
+90 (212) 221 60 61 info@testone.com.tr
  • İletişim
  • Fiyat Teklifi
Facebook Email Instagram linkedin
+90 (212) 221 60 61
TestOne Teknoloji Çözümleri TestOne Teknoloji Çözümleri
Menü
TestOne Teknoloji Çözümleri TestOne Teknoloji Çözümleri
  • Ana Sayfa
  • Hakkımızda
  • Ürünlerimiz
  • Ar-Ge
  • Kalibrasyon Laboratuvarı
  • Blog
  • İletişim
    • Teklif İsteyin
    • Müşteri Şikayet Formu
    • Müşteri Memnuniyet Anketi
    • Dış Paydaş Memnuniyeti Değerlendirme Formu
    • Kalibrasyon Başvuru Formu
Ana Sayfaİzolasyon / Yüksek Gerilim / Kaçak Akım / Topraklama Test Cihazlarıİzolasyon/Yüksek Gerilim (Delinme-Hipot) Test Cihazları Phenix BK180 -Mobile AC Dielectric Test Sets
Previous product
3205-Phenix-640-0.4P
Phenix 660-10P
Ürünlere geri dön
Next product
Phenix BK130/36-Mobile AC Dielectric Test Sets
Phenix BK130/36-Mobile AC Dielectric Test Sets
Phenix 6CP120/60-10
Resmi büyüt

Phenix BK180 -Mobile AC Dielectric Test Sets

Teklif İsteyin

AERIAL LIFT, ELEVATED PLATFORM, INSULATED BOOM TESTING

BKseries DATASHEET

Phenix Technologies offers a rugged, portable line of AC high voltage equipment for dielectric testing of aerial lift platforms and trucks. These units provide a complete testing solution in one convenient package. The standard safety features combined with advanced metering make the Phenix line of aerial lift high voltage test… Devamı

Kategoriler: İzolasyon / Yüksek Gerilim / Kaçak Akım / Topraklama Test Cihazları, İzolasyon/Yüksek Gerilim (Delinme-Hipot) Test Cihazları, VLF / AC-DC Yüksek Gerilim (HiPot) Test Cihazları Etiketler: izolasyon test cihazı, Phenix, Yüksek Gerilim
Paylaş
Facebook Twitter Pinterest linkedin WhatsApp WhatsApp
  • Açıklama
  • Ürün Özellikleri
  • Teknik Özellikler
  • Aksesuarlar
Açıklama

Phenix Technologies offers a rugged, portable line of AC high voltage equipment for dielectric testing of aerial lift platforms and trucks. These units provide a complete testing solution in one convenient package. The standard safety features combined with advanced metering make the Phenix line of aerial lift high voltage test systems the premium choice for testing single trucks to maintaining a whole fleet. The BK line of test equipment starts with the model BK130/36 which has the capability to test booms and liners to the boom only test equipment which is covered by models BK60 and BK180.

The precision digital metering equipped with a guard circuit to eliminate stray leakage currents ensures only boom leakage is measured. Standard safety features include a zero start interlock, adjustable output overload circuit and short and long term thermal magnetic protection. The oil-filled high voltage section is built in a rugged, fiberglass reinforced insulating tank which is light weight and durable for years of field use.

  • Lightweight and ruggedly constructed for years of field use
  • Units feature easy to read digital instrumentation and clean, efficient controls
  • Simple set-up and operation

GENERAL INFORMATION ON HIGH VOLTAGE TESTING

When we are ready to test in a High Voltage environment, general safety precautions should be taken into account as Hipot testers are capable of providing POTENTIALLY LETHAL VOLTAGES!

Improper operation or test practices may result in injury or death to the operator or surrounding personnel. The operation of High Voltage test equipment should only be performed by personnel familiar with HIGH VOLTAGE testing and safety procedures. The operator of this equipment must be aware of all hazards associated with High Voltage testing. The operator is responsible for himself and others in close proximity of the testing area.

Some General Safety Practices for working with High Voltage test equipment have been listed below for your reference.

  • Become familiar with your instrument before performing an actual test.
  • Know your work area, check that all circuits are de-energized and locked out.
  • Never work alone; always work with another qualified worker.
  • Mark off entire work area with barriers and warning tape.
  • Make all personnel aware of your testing activities.
  • Be aware of dangerous conditions that may arise from energizing a test specimen.
  • Never modify test equipment; modifications to equipment could introduce an unknown hazard or hinder a designed-in safety feature.
  • DO NOT operate damaged equipment. Remove power, and do not use the equipment until safe operation can be verified by service-trained personnel.

Terminology

The following terms relate to testing applications in the Electrical Laboratory or temporary Laboratory Set-up and in Test Stations.

High Voltage (HV)

Voltages exceeding 1000 V rms AC or 1000 V DC with current exceeding 2 mA AC or 3 mA DC.

Interlock

Safety circuit to prevent energizing HV generators until all access doors are closed, and immediately de-energizes HV if door is opened; this function does not necessarily ensure full discharge of stored energy.

Earthing System

HV test labs with earthing systems reduce potential increases and overvoltages to avoid danger to operators or control and measuring equipment.

Grounding/Discharge Stick

  • Before touching HV circuit components or leaving unattended and exposed, they must be de-energized and grounded with a grounding/discharge stick.
  • Grounding/discharge sticks must remain visible on HV terminal until circuit is re-energized; typically located near entrances to HV test station.
  • Automated grounding/discharge systems.

Safe Clearance

The minimum distance of HV component electrodes to safety fences.

Security Circuit

PHENIX builds in a Security Circuit or auxiliary safety control device on most test sets. This consists of a removable plug that has a shorting jumper installed to complete circuit. The jumper must be removed and cable connected to user supplied device if using this provision. This feature may prevent unauthorized use until the test process has been examined by safety personnel. Optional devices may be ordered including a Gate Switch, Foot Switch, or Deadman Switch to further ensure safety.

 

Ürün Özellikleri

Ürün Özellikleri

Teknik Özellikler

Teknik Özellikler

Aksesuarlar

Aksesuarlar

İlgili ürünler

Phenix_BK60-230
Kapat

Phenix BK60-Mobile AC Dielectric Test Sets

İzolasyon / Yüksek Gerilim / Kaçak Akım / Topraklama Test Cihazları, İzolasyon/Yüksek Gerilim (Delinme-Hipot) Test Cihazları, VLF / AC-DC Yüksek Gerilim (HiPot) Test Cihazları
AERIAL LIFT, ELEVATED PLATFORM, INSULATED BOOM TESTING
Teklif İsteyin
Phenix BK130/36-Mobile AC Dielectric Test Sets
Kapat

Phenix BK130/36-Mobile AC Dielectric Test Sets

İzolasyon / Yüksek Gerilim / Kaçak Akım / Topraklama Test Cihazları, İzolasyon/Yüksek Gerilim (Delinme-Hipot) Test Cihazları, VLF / AC-DC Yüksek Gerilim (HiPot) Test Cihazları
AERIAL LIFT, ELEVATED PLATFORM, INSULATED BOOM TESTING
Teklif İsteyin
Phenix 6CP30/15-3
Kapat

Phenix 6CP30/15-3

İzolasyon / Yüksek Gerilim / Kaçak Akım / Topraklama Test Cihazları, İzolasyon/Yüksek Gerilim (Delinme-Hipot) Test Cihazları, VLF / AC-DC Yüksek Gerilim (HiPot) Test Cihazları
FIELD and LAB AC HIPOTS
Teklif İsteyin
3205-Phenix-640-0.4P
Kapat

Phenix 660-10P

İzolasyon / Yüksek Gerilim / Kaçak Akım / Topraklama Test Cihazları, İzolasyon/Yüksek Gerilim (Delinme-Hipot) Test Cihazları, VLF / AC-DC Yüksek Gerilim (HiPot) Test Cihazları
AC VACUUM INTERRUPTER TEST SETS
Teklif İsteyin
Kapat

Hioki ST5520 DC İzolasyon test cihazı

İzolasyon / Yüksek Gerilim / Kaçak Akım / Topraklama Test Cihazları, İzolasyon Test Cihazları
Hioki ST5520 DC İzolasyon test cihazı
Teklif İsteyin
Kapat

Hioki 3153

İzolasyon/Yüksek Gerilim (Delinme-Hipot) Test Cihazları
DC 50V~1200V İzolasyon direnç testi, AC/DC 5000V Delinme voltaj testi
Teklif İsteyin
Hakkımızda Ürünler İletişim Site Haritası
Testone Teknoloji Çözümleri A.Ş.
Adres: Vadipark Seyrantepe Hamidiye Mah. Selçuklu Caddesi
No 10 C Blok 3. Kat 5 numara, 34418 Kâğıthane / İstanbul / Türkiye
Tel: +90 (212) 221 60 61 / 221 33 34
Faks: +90 (212) 222 9090
Email: info@testone.com.tr
 

TestOne Teknoloji Çözümleri, Konusunda deneyimli ve uzman kadrosu ile Test ve Ölçü aletleri alanında hizmet vermektedir.

Multimetre, Osiloskop, Meger, Pensampermetre, Termometre, Takometre, Trafo Test Cihazları, Güç Analizörü, Kalibratör, Güç kaynakları, Miliohmmetre, Mikroohmmetre, Termal Kameralar, Akü Test Cihazları, Datalogger, Oksijen Oranı Ölçüm Cihazı vb. Test ve ölçü aletleri satış ve teknik servis hizmetleri.

TestOne Teknoloji Çözümleri A.Ş. © 2020. Tüm Hakları Saklıdır.
KVKK Aydınlatma Metni - Gizlilik Sözleşmesi
  • Menü
  • Kategoriler
  • Ana Sayfa
  • Hakkımızda
  • Ürünlerimiz
  • Ar-Ge
  • Kalibrasyon Laboratuvarı
  • Blog
  • İletişim
    • Teklif İsteyin
    • Müşteri Şikayet Formu
    • Müşteri Memnuniyet Anketi
    • Dış Paydaş Memnuniyeti Değerlendirme Formu
    • Kalibrasyon Başvuru Formu
  • Ana Sayfa
  • Hakkımızda
  • Ürünlerimiz
  • Ar-Ge
  • Kalibrasyon Laboratuvarı
  • Blog
  • İletişim
    • Teklif İsteyin
    • Müşteri Şikayet Formu
    • Müşteri Memnuniyet Anketi
    • Dış Paydaş Memnuniyeti Değerlendirme Formu
    • Kalibrasyon Başvuru Formu
Scroll To Top