KIKUSUI PCR-WEA/WEA2 Series AC/DC Power Supply (CV/CF)

Teklif İsteyinFİYAT TEKLİFİ İÇİN TIKLAYIN!

KIKUSUI PCR-WEA/WEA2 Series AC/DC Power Supply (CV/CF) Compact size: 6kVA in 6U (PCR6000WEA2/PCR6000WEA2R) The 15 model line-up ranges from 1kVA to 36kVA 100% Regenerative-power capability (Only “R” models (PCR-WEA2R) with 3-phase 200V input. Regeneration on premises only.) Mix-and-match parallel operation up to 144kVA Same model set up is not required.… Devamı

Açıklama

KIKUSUI PCR-WEA/WEA2 Series AC/DC Power Supply (CV/CF)

  • Compact size: 6kVA in 6U (PCR6000WEA2/PCR6000WEA2R)
  • The 15 model line-up ranges from 1kVA to 36kVA
  • 100% Regenerative-power capability (Only “R” models (PCR-WEA2R) with 3-phase 200V input. Regeneration on premises only.)
  • Mix-and-match parallel operation up to 144kVA Same model set up is not required.
  • Achieves an extremely low switching noise for a PWM inverter-type AC power supply.
  • Power-saving function

 

PCR-WEA/WEA2 Series

PWM Inverter Type – Programmable AC Power Supply The PCR-WEA/WEA2 Series brings new innovations to the power-electronics industry.

The PCR-WEA/WEA2 is a series of multifunctional switching AC power supplies that combines accurate, high-power output with an ultra-compact design. The 15 model line-up ranges from 1 kVA to 36 kVA AC/DC with single & 3-phase variable output from 6 kVA and up. The PCR-WEA2 also features a regenerative mode*1 that can drastically reduce power consumption and cut operating costs. The PCR-WEA2/WEA2R also supports mix-and-match parallel operation*2 up to 144kVA for large-scale test systems. Output frequency up to 5kHz is also available with all models, which is critical for AC applications in avionic industries.*1 Only “R” models (PCR-WEA2R) with 3-phase 200 V input. For regeneration within the installation site only. *2 Parallel operation is available for 6kVA models and up, with a maximum of 4 units. Same model combination is not required.

 

ModelPCR-WE/WE2 SeriesPCR-WEA/WEA2 Series
FirmwareVer 1.24Ver 3.12
Basic functionOutput voltage
155/310 Vrms
±219/438 Vdc
Output voltage
160/320 Vrms
±226/452 Vdc
Applied functionsSame value regardless of the lower limit
response setting for output impedance
(reactance component).
Lower limit of output impedance (reactance component)
FAST : reduced by 50 %
MED : no change
SLOW : 3x
InterfaceNoneAddition of analog monitor output option (factory option)
*On PCR6000WEA and higher models, analog monitor output (factory option) is possible.

 

 

 